Fluke Ti50FT-10/20 IR-Fusion FlexCam Thermal Imager with best priceLarge, sharp thermal images Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments.
A sharp image in every situation The innovative 180° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring.
| Characteristics: | Fluke TI50FT-10-20 Thermal Imager Camera FlexCam |
| High resolution, low noise VOx detector for high quality images | |
| Temperature range to cover broad industrial applications | |
| High thermal sensitivity for viewing even the smallest temperature differences | |
| 180º articulating flexible lens to view images in every situation | |
| Large 5″ high contrast color LCD for a clear picture independent of lighting conditions | |
| Fully radiometric for detailed temperature analysis and tracking | |
| SmartFocus for best image quality and accurate temperature measurements | |
| Windows CE based menu structure for ease of use | |
| Personalized instrument set-up for multiple use | |
| CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data | |
| SmartView reporting and analysis software included | |
| Built-in visible light (digital) camera | |
| Laser pointer for easy targeting | |
| Flash and torch light for high quality images in dark environments |
| Applications: | Fluke TI50FT-10-20 Thermal Imager Camera FlexCam |
| Troubleshooting | Pinpointing the location of specific problems in equipment and systems |
| Preventive/predictive maintenance | Identify electrical and mechanical problems before they cause failure |
| Industrial maintenance | Check whether repairs have been performed correctly |
| Process monitoring | Real-time observation to ensure efficient and safe operations |
| Electronic design | Close up circuit board analysis |
| Quality control | Examine prototypes and refine thermal management designs |
| Research and development | Quantify heat patterns to improve product designs |
| Fluke Ti50FT-10/20 IR-Fusion FlexCam Thermal Imager Specifications: | Fluke TI50FT-10-20 Thermal Imager Camera FlexCam |
| Imaging Performance | |
| Field of view (FOV)* | 23° horizontal x 17° vertical |
| Spatial resolution (IFOV)* | 1.30 mrad |
| Min focus distance* | 0.15 m (5.9 in) |
| Thermal Sensitivity (NETD) | ≤ 0.07 °C at 30 °C (70 mK) |
| Frequency | 60 Hz |
| Focus | SmartFocus; one finger continuous focus (manual) |
| Zoom | 2x |
| Resolution | 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer |
| Spectral band | 8 μm to 14 μm |
| Digital image enhancement | Automatic full time enhanced |
| On camera operating modes | Full thermal, full visual light or merged thermal-visual images. |
| Picture-In-Picture | Yes |
| Fusion | Yes |
| Visible light camera | 1280 x 1024 pixels, full color |
| Visible light digital zoom | 2x |
| *Standard 20 mm Germanium lens | |
| Temperature measurement | |
| Temperature Range | -20 °C to 350 °C (-4 °F to 662 °F) in two ranges Range one = -20 °C to 100 °C (-4 °F to 212 °F) Range two = -20 °C to 350 °C (32 °F to 662 °F) |
| Accuracy | ± 2 °C or 2 % (whichever is greater) |
| Measurement modes | Centerpoint, center box (area min/max, average) |
| Emissivity correction | 0.1 to 1.0 (0.01 increments) |
| Image presentation | |
| Digital display | 13 cm (5 in) diagonal large high-resolution digital display |
| LCD backlight | Sunlight readable color LCD |
| Video output | RS170 EIA/NTSC or CCIR/PAL composite video |
| Palettes | Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted |
| Optical lenses | |
| 10.5 mm wide angle lens | Field of view (FOV): 42° horizontal x 32° vertical Spatial resolution (IFOV): 2.45 mrad Min focus distance: 0.3 m (0.98 ft) |
| Image and data storage | |
| Storage medium | Compact flash card stores over 1000 IR images (1 GB card standard) |
| File formats supported | 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff; Data formats: comma separated (csv), tab separated (txt). |
| Interface and software | |
| Interface | Compact flash card reader included |
| Software | SmartView; Full analysis and reporting software included |
| Laser | |
| Classification | Class II |
| Laser targeting | Laser dot visible on screen when blending thermal and visible image |
| Controls and adjustments | |
| Set-up controls | Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low) |
| Image controls | Level, span, auto adjust (continuous/manual) |
| On-screen indicators | Battery status, target emissivity, background temperature and realtime clock |
| Power | |
| Battery type | Li-Ion smart battery, rechargeable, field-replaceable (two included) |
| Battery operating time | Two hours continuous operation (per battery) |
| Battery charging | Two bay intelligent charger powered via ac outlet |
| Power saving | Automatic shutdown and sleep modes (user specified) |
| Environmental and mechanical design | |
| Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature | -40 °C to +70 °C (-40 °F to 158 °F) |
| Relative humidity | Operating and storage 10 % to 95 %, non-condensing |
| Water and dust resistant | IP54 |
| Weight (including batteries) | 1.95 kg (4.3 lb) |
| Camera size (H x W x D) | 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in) |
| Other | |
| Warranty | Two-years |